WIRING TERMINALS & CONNECTORS
LOCK RELEASE OUTPUT FOR SOLENOID LOCKS.
Figure 15 shows how to connect an electric solenoid lock
to the control board’s lock release output. Note the lock release
output only switches the applied voltage to the lock and must be
“wetted” with the appropriate voltage.
ATA Electric impulse lock Order code 90101.
Figure 15: Wiring solenoid locks
CONTROL AND SAFETY INPUT TERMINALS.
Figure 14 shows how to wire the control and safety input
terminals to switches, such as a Photo Electric Beam. Note that
the P.E., OPN and STP inputs require a normally closed contact,
which is provided by the shunts (see Fig 11 and Fig 14).
The appropriate shunt must be removed when the P E, OPN
or STP inputs are used. The CLS, OSC and PED inputs require
a normally open contact.
ATA Photo Electric Beams are available:-
Order code 90214 for receiver/transmitter type.
Order code 91315 for reflective type.
Figure 14: Wiring control and safety inputs.
LOCK RELEASE OUTPUT FOR MAGNETIC LOCKS.
Figure 16 shows how to connect an electromagnetic lock to the
control board’s lock release output. Note the lock release output only
switches the applied voltage to the lock and must be wetted with the
appropriate voltage (24VDC in the example shown).
Note that the lock is connected to the normally closed contact of the
lock release output as the lock is energised when the controller is idle
and not driving the motors. Note the lock output's action will need to
be programmed for a hold action when this type of lock is used.
Figure 16: Wiring magnetic locks
LIGHT CONTROL RELAY MODULE.
Figure 17 shows how to connect the optional relay module to
the
control board’s connector [21]. It also shows how to wire a light
to the relay module. ATA supply this with a 240VAC to
24VDC relay. Any voltage relay can be used provided the relay
module is able to switch the required voltage and current. Make
sure any mains voltage lighting is properly earthed.
E.g., Use this to control lights on a gate pillar, garden lights or
security lights.
ATA order code 90111.
Figure 17: Wiring light control relay module.
Page 16